Magnaflux EV6000 MG Kit

Magnaflux EV6000 MG Kit

Item# 626779
$2,153.00
Availability: Discontinued
Ship weight: 19 lbs
This item is currently out of stock!

ORM-D GROUND ONLY. Aerosols can only be shipped via UPS Ground within the continental U.S. or Canada.

LED UV Lamp Fluorescent Magnetic Particle Testing Kit

EV6000 MG Kit is a convenient collection of Magnaflux’s portable, hand-held EV6000 LED UV lamp with fluorescent magnetic particles in easy-to-use aerosol form.Each testing kit comes with 14AM oil-based fluorescent magnetic particle suspension, SKC-S cleaner/remover, SCRUBS® hand cleaner towels, a DYKEM® Brite-Mark yellow paint marker and a shop cloth.The EV6000 MG Kit is portable and great for job sites or field inspections to detect very fine to fine discontinuities, check critical applications, after secondary processing, in-service inspections, testing high strength alloys and many other applications. 

Kit Includes:

  • EV6000 LED UV lamp
  • 2 Cans of 14 AM
  • 2 Cans of SKC-S
  • Paint Marker
  • SCRUBS™ Hand Towels
  • Portable Carrying Case and Instructions
  • NOTE: No Yoke or Coil Included

Benefits & Features

  • Pre-packaged set of products provides everything needed for wet method fluorescent magnetic particle testing
  • Clear, bright indications
  • High sensitivity magnetic particles
  • EV6000 has a 9 in / 23 cm wide, uniform circular beam
  • Convenient carrying case

Specifications

Specifications / Standards:

  • ASTM E2297
  • ASTM E3022
  • ISO 3059
  • RRES 90061
  • ASTM E3022

Fluorescent Magnetic Particle Testing Specifications / Standards:

  • ASME BPVC
  • ASTM E709
  • ASTM E1444
  • ASTM E3024
  • ISO 9934
  • NADCAP AC7114/2

Applications

Defect location: surface and slightly subsurface

Ideal for:

  • Detecting very fine to fine discontinuities
  • Critical applications
  • After secondary processing
  • In-service inspections
  • High strength alloys

Defect examples:

  • Inclusions
  • Seams
  • Shrink cracks
  • Tears
  • Laps
  • Flakes
  • Welding defects
  • Grinding cracks
  • Quenching cracks
  • Fatigue cracks

Use Recommendations

NDT Method: Magnetic Particle Testing, Fluorescent, Wet Method

Suspension Vehicle: Carrier II (petroleum distillate)

Required Equipment: Magnetizing device

Temperature Range: 55 to 120°F / 13 to 49°C

Recommended Accessories:

  • UV-A Meter PN 625024
  • Visible Light Meter PN 622338
  • UV-A Safety Glasses PN 506249