Magnaflux Zyglo ZL-67 Penetrant - Level 3 - 20 Gallon Drum
Magnaflux ZL-67 Level 3 Water Washable Fluorescent Penetrant
A high-sensitivity Level 3 penetrant, ZL-67 fluorescent water removable penetrant is designed to find smaller, finer indications in safety-critical components common to aerospace and engineering applications. ZL-67 penetrant is often used to find flaws in investment castings, jet engine components, and highly machined surfaces.
ZL-67 is specially formulated for strong capillary action which allows it to penetrate defects quickly and bleed out into developer faster and more completely than other penetrants for stronger, higher contrast indications that are easier for inspectors to identify, even when the defects are very fine.
ZL-67 is listed on the QPL SAE AMS 2644 Qualified Product List and is approved for use by Pratt & Whitney.
Recommended developers are ZP-4B dry powder, SKD-S2 or ZP-9F solvent-based, and ZP-5B suspendible developers.
Improve indication detection
Clear, bright, indications appear every time due to high UV and thermal stability
Higher contrast indications form due to strong capillary action, making them easier to spot
Inspect a wide range of high-value components without fear of corrosion or specification non-conformance
Promotes better inspection quality by providing the operator with a more comfortable work environment
Reduces discomfort from strong odors
Exceeds all EHS requirements
Maintain penetrant system performance over longer periods of time thanks to low volatility and high water tolerance
- Level 3 high sensitivity
- Water washable
- Bright, high-contrast indications
- High flash point
- Wide range of application methods
- Controlled washability
- Low odor
- Very low toxicity
- Alloy compatibility
- High water tolerance
- High thermal resistance
- High UV stability
- Optimized capillary action
- Low volatility
- QPL SAE AMS 2644 Qualified Product List
- Approved for use by Pratt & Whitney
Specifications
- AECL
- AMS 2644
- ASME BPVC
- ASTM E1417
- ASTM E165
- Boeing BAC 5423 PSD 6-46 or 8-4
- Boeing PS-21202
- GE P3TF2
- Honeywell EMS 52309
- ISO 3452-2
- MIL-STD-2132
- MIL-STD-271
- NAVSEA T9074-AS-GIB-010/271
- Pratt & Whitney PMC 4360
- QPL SAE AMS 2644
Applications
Defect location: open to surface
Ideal for:
- Precision castings
- Precision forgings
- Machined components
- Aerospace inspections
- Engineering applications
- Investment castings
- Jet engine components
- Highly machined surfaces
- Aerospace alloys
- Aluminum
- Steel
- Nickel
- Titanium
Defect examples:
- Cracks
- Seams
- Porosity
Use Recommendations
NDT Method: Fluorescent Penetrant Testing
Type: Type 1
Methods: Method A or Method C
Sensitivity Level: Level 3, high sensitivity
Required Equipment: UV light source, like the EV6000
Temperature Range: 40 to 125°F / 4 to 52°C
Container Size & Part Number
5 gal / 18.9 L pail 01-3274-40
20 gal / 75.7 L drum 01-3274-30
55 gal / 208 L drum 01-3274-45